Facilities Design Information (FDI) is a set of documents and drawings maintained as
Microsoft Word and Autocad files. The FDI states the design
standards for all work on UW buildings and leased buildings. Designers and
consultants working on projects involving UW facilities should use these
documents and drawings in preparing project specifications.
These drawings are in two forms; low resolution graphics and AutoCAD
files. The graphics are intended for viewing only and should not be used in
project documentation. Consultants and designers developing project
specifications should copy and work with the AutoCAD files.
| Drawing Name |
Acrobat PDF File |
AutoCAD DWG File |
Standard Communications Drafting Symbols
SD-CM-1
01CM-SYM.DWG:8/1/02
|
|
|
Voice/Enet Intra-building Elements
SD-CM-2
02BLD-L.DWG:8/1/02
|
|
|
CATV Intra-building Elements, Fiber-based Input to MDF
SD-CM-3
03CTV-FL.DWG:8/1/02
|
|
|
CATV Intra-Building Elements, Coax-based Input to MDF
SD-CM-4
04CTV-CL.DWG:8/1/02
|
|
|
MDF/IDF Room Analysis Worksheet
SD-CM-5
05AN-WKS.DWG:8/1/02
|
|
|
Typical Communications Floor Plan
SD-CM-6
06TYP-FL.DWG:8/1/02
|
|
|
Typical Outlet Schedule
SD-CM-7
07OUTSCH.DWG:8/1/02
|
|
|
Infrastructure, Typical Riser Schematic
SD-CM-8
08R-INF.DWG:8/1/02
|
|
|
Cable Plant, Typical Riser Schematic
SD-CM-9
09R-CPL.DWG:8/1/02
|
|
|
Infrastructure, Typical Systems Coordination Diagram
SD-CM-10
10SYS-CO.DWG:8/1/02
|
|
|
Communications Equipment Grounding Conductor
SD-CM-11
11GRCOND.DWG:8/1/02
|
|
|
Suggested Ground Bus Bar Assembly
SD-CM-12
12GRBUSB.DWG:8/1/02
|
|
|
Vault Butterfly Diagram
SD-CM-13
13VAULT.DWG:8/1/02
|
|
|
Typical Router Room Diagram
SD-CM-14
14RTR-RM.DWG:8/1/02
|
|
|
Infrastructure, Typical MDF Room, Elevation
SD-CM-15
15MDF-L.DWG:8/1/02
|
|
|
Infrastructure, Typical MDF Room, Plan
SD-CM-16
16MDF-PL.DWG:8/1/02
|
|
|
Infrastructure, Typical Walk-in IDF Room, Elevation
SD-CM-17
17IDFW-L.DWG:8/1/02
|
|
|
Infrastructure, Typical Walk-in IDF Room, Plan
SD-CM-18
18IDFW-P.DWG:8/1/02
|
|
|
Infrastructure, Typical Shallow IDF Room, Elevation
SD-CM-19
19IDFS-L.DWG:8/1/02
|
|
|
Infrastructure, Typical Shallow IDF Room, Plan
SD-CM-20
20IDFS-P.DWG:8/1/02
|
|
|
Cable Plant, Typical MDF Room Backboard, Elevation
SD-CM-21
21MDF-BB.DWG:8/1/02
|
|
|
Cable Plant, Typical IDF Walk-in Room Backboard, Elevation
SD-CM-22
22IDFW-B.DWG:8/1/02
|
|
|
Cable Plant, Typical IDF Shallow Room Backboard, Elevation
SD-CM-23
23IDFS-B.DWG:8/1/02
|
|
|
Fiber Elements, Router Room to MDF Room
SD-CM-24
24CATV-RR.DWG:8/1/02
|
|
|
Fiber Elements, MDF Room to IDF Room
SD-CM-25
25CATV-IDF.DWG:8/1/02
|
|
|
Wireless Infrastructure
SD-CM-26
26WR-INF.DWG:8/1/02
|
|
|
Plastic Faceplate, Standard Bundle (CATV Fiber optional), Assembly Detail
SD-CM-27
27PLSTC8.DWG:8/1/02
|
|
|
Stainless Steel Faceplate, Standard Bundle, Assembly Detail
SD-CM-28
28STNLS4.DWG:8/1/02
|
|
|
Custom Plastic Faceplate, CATV, Assembly Detail
SD-CM-29
29CATV4.DWG:8/1/02
|
|
|
Wall-Mounted Telephone, Assembly Detail
SD-CM-30
30WALLPH.DWG:8/1/02
|
|
|
Plastic Faceplate, Existing Single-gang Box, Assembly Detail
SD-CM-31
31EX-SG.DWG:8/1/02
|
|
|
Surface-mount Box, Assembly Detail
SD-CM-32
32SUR-MT.DWG:8/1/02
|
|
|
Termination Device, WireMold 3000, Assembly Detail
SD-CM-33
33WM-3K.DWG:8/1/02
|
|
|
Termination Device, Divided WireMold 4000, Assembly Detail
SD-CM-34
34WM-4KD.DWG:8/1/02
|
|
|
Termination Device, Isoduct 300, Assembly Detail
SD-CM-35
35ISO300.DWG:8/1/02
|
|
|
Termination Device, Divided Isoduct 452, Assembly Detail
SD-CM-36
36ISO452.DWG:8/1/02
|
|
|
Co-located Communications/Power Floor Boxes, Assembly Detail
SD-CM-37
37FB-2CO.DWG:8/1/02
|
|
|
In-floor Outlet Box, WireMold Power/Communication Poke-through, Assembly Detail
SD-CM-38
38FB-PKTH.DWG:8/1/02
|
|
|
Podium Floor Box, Details and Orientation
SD-CM-39.1
39.1PD&O.DWG:8/1/02
|
|
|
Pofium Floor Box, New and Existing Conditions
SD-CM-39.2
39.2PN&E.DWG:8/1/02
|
|
|
Podium Floor Box, Spider Mfg. Concrete Pour Box, Detail
SD-CM-39.3
39.3P701.DWG:8/1/02
|
|
|
Podium Floor Box, Spider Mfg. Communication/Power Box, Detail
SD-CM-39.4
39.4P704.DWG:8/1/02
|
|
|
Podium Floor Box, Spider Mfg. Multimedia Box, Detail
SD-CM-39.5
39.5P706.DWG:8/1/02
|
|
|
Elevator Telephone
SD-CM-40
40PELEV.DWG:8/1/02
|
|
|
Direct-connect 911 Telephone
SD-CM-41
41P911.DWG:8/1/02
|
|
|
Weatherproof Touch-tone Telephone
SD-CM-42
42PWTHPR.DWG:8/1/02
|
|
|
Emergency Code Blue Telephone
SD-CM-43
43PCDBLU.DWG:8/1/02
|
|
|
Jack Position Configurations
SD-CM-44
44JCKCON.DWG:8/1/02
|
|
|
Test Form, Single Mode Optical Fiber Cable - Outside Plant
SD-CM-45
45TF-FSO.DWG:8/1/02
|
|
|
Test Form, Single Mode Optical Fiber Cable - Riser/Station
SD-CM-46
46TF-FSR.DWG:8/1/02
|
|
|
Test Form, Multimode Optical Fiber Cable - Outside Plant
SD-CM-47
47TF-FMO.DWG:8/1/02
|
|
|
Test Form, Multimode Optical Fiber Cable - Riser/Station
SD-CM-48
48TF-FMR.DWG:8/1/02
|
|
|
Test Form, Coaxial Cable
SD-CM-49
49TF-CX.DWG:8/1/02
|
|
|
Test Form, CATV Cable
SD-CM-50
50TF-CTV.DWG:8/1/02
|
|
|
Test Form, Video/TV Coaxial Cable
SD-CM-51
51TF-VTV.DWG:8/1/02
|
|
|
CAT6
SD-CM-52
52CAT6.DWG:8/1/02
|
|
|